Standards » IECEx

Standards Documentation for Purchase. The IECEx System is based on the use of International Standards, such as IEC Standards. These Standards are dedicated to the highly specialised fields associated with the use of equipment, termed Ex equipment, and installations in areas where a potential may exist of fire or explosion.

 Chat Online

PDF IECEx Certificate of Conformity

IEC 60079-0 : 2011 Edition:6.0 Explosive atmospheres - Part 0: General requirements IEC 60079-1 : 2014-06 Annex to: IECEx EXV 12.0002X Issue 0 Page 1 of 1 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, FO-CB-34 V1 Wrexham, United Kingdom LL13 9UZ.

 Chat Online

ATEX Protection Concepts | Ex Equipment References

1 and 2: IEC BS EN 60079-1: Contains explosion and flame quenched: Increased safety: e: 1 and 2: IEC BS EN 60079-7: No arcs, sparks or hot surfaces: Non-Sparking: nA: 2: IEC BS EN 60079-15: No arcs, sparks or hot surfaces: Pressurised: p: 1 and 2: IEC BS EN 60079-2: Keep flammable gas out: Oil immersed: o: 1 and 2: IEC BS EN 60079-6: Keep

 Chat Online

Pressure Transmitters ATEX/IECEx Safety Information

IECEx ATEX Ex ia IIC T4 Ga Ex ia IIIC T85ºC Da Ta = -40°C to +80°C Ta = -50°C to +80°C (For model code option 'J' only) II 1GD Ex ia IIC T4 Ga Ex ia IIIC T85ºC Da Ta = -40°C to +80°C Ta = -50°C to +80°C (For model code option 'J' only) IEC 60079-0:2017 Ed. 7 IEC 60079-11:2011 Ed. 6 EN 60079-0:2017 EN 60079-11:2012

 Chat Online

PDF IECEx Certificate of Conformity - R. STAHL

IECEx Certificate of Conformity Certificate No.: IECEx PTB 06.0016U Date of Issue: 2015-03-11 Issue No.: 1 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): 1) New test according to IEC 60079-0:2011 (Ed. 6), IEC 60079-1:2007 (Ed. 6), IEC 60079-7:2006 (Ed. 4), IEC 60079-11:2011 (Ed. 6) 2) New material (D0021-02) for the

 Chat Online

PDF IECEx Certificate of Conformity - Rotork

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx FMG 17.0006X Issue No: 0 Certificate history: Issue No. 0 (2017-04-19) Status: Current Page 1 of Date of Issue: 2017-04-19

 Chat Online

PDF Gbstrp05-20160705160815

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITS 15.0068X Issue No: 1 Certificate history: Issue No. 1 (2016-11-23) Status: Current Page 1 of Issue No. 0 (2016-06-07)

 Chat Online

PDF IECEx Certificate of Conformity - eaton.com

IECEx Certificate of Conformity Certificate No: IECEx INE 12.0025X Issue No: 5 Date of Issue: 2019-07-01 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Purpose of the issue 1 of IECEx INE 12.0025X: •Addition of the following cable glands with sealing ring: - ADE-1F2 sizes N°14 to 17 and ADE-1F2 anchorage sizes N°3 to 17

 Chat Online

PDF IECEx Certificate of Conformity - Emerson Electric

standards IEC 60079-0, IEC 60079-1 as Ex d IIB+H2, T6, for an ambient temperature of -20°C to +60°C. The product has the following electrical ratings: 21-30 V d.c., max. 150 W The 370XA Gas Chromatograph is assessed to the

 Chat Online

PDF Spec-00714 zonEX atEX- and iEcEX-cErtifiEd, typE 4X

zonEX atEX- and iEcEX-cErtifiEd, typE 4X, HingEd covEr industry standards atEX directive 94/9/Ec atEX Sira 09ATEX3224U Ex e IIC Gb Ex tb IIIC Db IP 66 EN60079-0:2009 EN60079-7:2007 EN61241-0:2006 EN61241-1:2004 iEcEx IECEx SIR 09.0099U Ex e IIC Gb Ex tb IIIC Db IP 66 IEC 60079-0:2007-2010 IEC 60079-7:2006-2007 IEC 61241-0:2004 IEC 61241-1:2004

 Chat Online

PDF IECEx Certificate - Endress+Hauser

Annex 1 to Certificate of Conformity IECEx KEM 09.0016, issue 3 Page 1 of 2 Form 124 Version 1 (2011-02) DEKRA Certification B.V. Utrechtseweg 310, 6812 AR Arnhem P.O. Box 5185, 6802 ED Arnhem The Netherlands T +31 26 3 56 20 00 F +31 26 3 52 58 00 www.dekra-certification.com Registered Arnhem 09085396 Description

 Chat Online

ATEX and IECEx Standards for Intrinsically safe load cells

ATEX - II 1 G IECEx - ia IIC T4 Ga. Example: For Straightpoint, current ATEX/IECEx equipment markings the protection concepts are: ATEX - II 1 G where: Equipment Group II is for use in all other areas other than mines. Category 1 for use Zones 0, 1 and 2 for gases/vapours. Environment G for use in hazardous gas, vapour or mist environments.

 Chat Online

PDF Guide to Equipment Certification Requirements

1,2 2 IEC 6 0 79-IEC 60079-15 No arcs, sparks or hot surfaces Enclosure IP54 or better d Gb 1,2 IEC 60079-1 Contain the explosion, Type 'n' (Enclosed Break) nC Gc 2 IEC 60079-15 quench the flame Gb 1,2 nC--[ATEX & IECEx] and ® ® ® ® Equipment Equipment II Equipment

 Chat Online

Hazloc Heaters XET1-1-E-A Electronic Explosionproof

Hazloc XET1-1-E-A is an electronic thermostat for heating applications only including unit and convection hazardous area heaters requiring a 24VAC control with an IP66 rating and suitable for a hydrogen gas atmosphere (Zone Group IIB+H 2) - XET1. The hazardous area thermostat has a temperature adjustment range of 5°C to 25°C, is extremely rugged, has a very fast acting electronic

 Chat Online

PDF IECEx Certificate of Conformity - WIKA

The width of the flameproof joints is superior than the values specified in the tables of 60079-1 standard. Annex: IECEx INE 13.0091X-00_Annex.pdf Page 3 of3. IECEx Certificate of Conformity Certificate No.: IECEx INE 13.0091X Date of Issue: 2013-12-20 Issue No.: 0 Page 1 of 1 In accordance with § 16.2 of the IEC 60079-1 standard, the

 Chat Online

Hazardous Area Classification and Control of Ignition Sources

Hazardous Area Classification and Control of Ignition Sources. The use of BS EN 60079-14 1 and the Institute of Petroleum Code 'Area Classification Code for Petroleum Installations: Model Code of practice in the Petroleum Industry' Part 15 are recommended. This is aimed mainly at small scale handling, with containers of 200 litres or less.

 Chat Online

PDF Abe Gland Ne Compliant

UL2225, UL514B, CSA C22.2 NO. 18.3-12 , CSA 22.2 60079-0, CSA 22.2 60079-1, CSA 22.2 60079-7 and CSA 22.2 60079-31 ATEX/IECEx ATEX/IECEx Protection Class Ex II 2GD Ex db IIC Gb; Ex eb IIC Gb; Ex nR IIC Gc; Extb IIIC Db ATEX Certificate No CML 18ATEX1268X CML 19ATEX4507 (Ex nR) IECEx Certificate No CML 18.0131X Construction & Test Standards IEC

 Chat Online

PDF IECEx Certificate of Conformity - BARTEC

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres IECEx PTB 09.0008U Iss. 6 1 IEC 60079-0:2011, Ed. 6 IEC 60079-7:2006, Ed. 4 1 IEC 60079-31:2013, Ed. 2 Self-limiting heating cable 07-5803-****

 Chat Online

PDF IECEx Certificate of Conformity - eltherm

60079-30-1:2007. 2. An electric strength test of the polymeric sheath (overjacket) used for corrosion resistance shall be carried out in accordance with the requirements of IEC 60079-30-1:2007 clause 5.2.1. 3. The manufacturer shall verify the output rating for each cable manufactured in accordance with IEC 60079-30-1-2007 clause 5.2.2. 4.

 Chat Online

Zonex ATEX- and IECEx-Certified, Type 4X | Products

Industry Standards: ATEX Directive 94/9/EC ATEX Sira 09ATEX3224U Ex e IIC Gb Ex tb IIIC Db IP 66 EN 60079-0:2009 EN 60079-7:2007 EN 61241-0:2006 EN 61241-1:2004 IECEx IECEx SIR 09.0099U Ex e IIC Gb Ex tb IIIC Db IP 66 IEC 60079-0:2007-2010 IEC 60079-7:2006-2007 IEC 61241-0:2004 IEC 61241-1:2004 AEx/Ex UL File E67456 Class I, Zone I AEx e IIC Tamb -20C to +60C Ex e IIC U Tamb -20C to +60C UL

 Chat Online

PDF Certificate of Conformity

en 60079-0:2012 + a11:2013, en 60079-1:2014, en 60079-31:2014, EN 60529:1991 + A1:2000 + A2:2013 10 If the sign 'X' is placed after the certificate number, it indicates that the equipment is subject to specific

 Chat Online

PDF IEC IECEx Certificate of Conformity - Heating and Process

IECEx Certificate of Conformity IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx LCI 09.0005X Status: Current IEC 60079-1 : 2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures

 Chat Online

Electrostatic hazards and Ex equipment - application of

We can assess and test your products against IECEx standards and supply you with an IECEx certificate of conformity (C of C) and test report (ExTR). For more information on using IECEx approvals to gain access to international markets please see our market access section. References: IEC 60079-0 Ed 6. IEC 60079-32-1 Ed 1

 Chat Online

Iec 60079-1 : Explosive Atmospheres - Part 1: Equipment

ASME Boiler & Pressure Vessels. ASTM Book of Standards. National Board NBIC (NB 23) Drawing and Drafting. Power & Process Piping. IEC 60079-1 7th Edition, June 2014. Complete Document EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" Includes

 Chat Online

IECEx certification - Electrical equipment for explosive

The IECEx scheme is an international system equivalent to the IECEE CB scheme, but especially defined for explosion protected equipment. The objective of the IECEx system is to facilitate international trade in equipment and services for use in explosive atmospheres, while maintaining the required level of safety.Presafe is an approved test laboratory and certification body within the IECEx

 Chat Online

PDF IECEx Certificate of Conformity - Norgren

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 16.0033X Issue No: 2 Certificate history: Issue No. 2 (2019-02-25) Issue No. 1 (2018-08-29) Issue No. 0 (2016-06-06) Status: Current

 Chat Online

PDF Day 2 0830-0915 IECEx Dubai Area Classif final Leroux P

Excluded as per IEC 60079-10-1 IEC 60079-10-1 Classification of areas - Explosive gas atmospheres Standard intended to be applied where there may be an ignition hazard due to the presence of flammable gas orpresence of flammable gas or vapour, mixed with air under normal, mixed with air under normal atmospheric conditions but does not apply to :

 Chat Online

IECEx Certificate of Conformity

IEC 60079-29-1 IP66 IP66 *Output Communication Option 1 (Analog/HART/Relays) only suitable for Ex db, Ex db nA and Ex tb. Notes to Standard IEC 60079-29-1: 1. Applies only to the ULTIMA ®X5000 Gas Monitor fixed Combustible Gas Detection System. 2.

 Chat Online

PDF IECEx Certificate of Conformity - Federal Signal Corporation

Flamepath joint differs from Table 2 of IEC 60079-1. The enclosure has joint width of 37 mm, maximum allowable gap of 0.038 mm. The distance 'I' of 22.6 mm is measured from the edge of the o-ring groove to the edge of the cover bolt per Figures 3 and 5 of IEC

 Chat Online

PDF IECEx Certificate of Conformity - BARTEC

Section 1 of IEC 60079-0. 1. When the components are installed in an increased safety enclosure that complies with IEC 60079-7, the creepage and clearance distances must comply with the requirements of Table 1. 2. The components may be operated in an intrinsically safe or a non-intrinsically safe operation mode. The operation mode is specified in

 Chat Online

PDF IECEx Certificate ofConformity - Emerson Electric

IECEx BAS 11.0022X 2014-04-10 IECEx Certificate ofConformity Issue No: 1 Page 4of DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 1.1 To add alternative manufacturing locations only. IFile Reference: 14/0355 Annex: IECEx BAS 11.0022X Annex Issue O.pdf

 Chat Online

PDF IECEx Ex TEST REPORT COVER - Emerson Electric

IECEx TEST REPORT IEC 60079 Electrical equipment for explosive gas atmospheres Part 0: General requirements . IECEx TEST REPORT Section 1 To be completed by ExCB Page 7 of 34 ExTR: GB/BAS/ExTR10.0134/00 IEC 60079-0:2007 Edition 5 Clause Requirement - Test Result - Remark Verdict

 Chat Online

International Standard 60079-1 - Sis

As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the

 Chat Online

PDF IECEx Certificate of Conformity - Pelican

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx TRC 11.0010X issue No.:0 Status: Current Date of Issue: 2012-03-13 Page 1 of 3 Applicant: Electrical Apparatus: Flashlight / Head Torch 2690

 Chat Online

PDF Ul Hazardous Locations Services

Note 1: Zone 0, 1 and 2 general requirements are contained in UL 60079-0 (UL Mark), CSA 60079-0 (C-UL Mark), IEC 60079-0 (IECEx) and EN 60079-0 (ATEX). Applicable Certification Documents Area Protection Techniques UL Mark C-UL Mark IECEx ATEX Zone 20 • Constructional safety, "c" (Da) — — ISO 80079-37 EN ISO 80079-37

 Chat Online

PDF IECEx Certificate of Conformity - s3-eu-west-1.amazonaws.com

Note 1-20°C to +200°C Note2 Note 1 When fitted with the standard seal Note 2 When fitted with the high temperature seal Approved for issue on behalf of the IECEx Certification Body: P J Walsh Position: Technical Advisor Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2.

 Chat Online

PDF Ul Hazardous Locations Services

Note 1: Zone 0, 1 and 2 general requirements are contained in UL 60079-0 (USA), CSA 60079-0 (Canada) and IEC/EN 60079-0 (IECEx System & Europe). Note 2: Zone 0, 1 and 2 intrinsically safe system requirements are contained in ISA 60079-25 (USA), CSA 60079-25 (Canada) and IEC/EN 60079-25 (IECEx System & Europe).

 Chat Online

PDF IECEx Certificate of Conformity - Flowserve

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx FMG 13.0038X Issue No: 1 Certificate history: Issue No. 1 (2014-05-22) Status: Current Page 1 of Issue No. 0 (2013-12-18)

 Chat Online

ITS-Ex - Glenair

Series ITS-Ex is designed for easy and repeatable termination of armored and unarmored cables built to IEEE 45, IEC, BS, DIN, and JIC standards. A full range of power and signal contacts, from size #16 to size #0 in over 40 insert arrangements are available to address all common voltage, wire size and connector service class ratings.

 Chat Online

PDF IECEx Certificate of Conformity

Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition:6.0 Explosive atmospheres - Part 0: General requirements IEC 60079-1 : 2014-06

 Chat Online